1.	To install "Free Stroke Analyser" or to update the software version: 

	Run the "Install FSA.bat" file by double clicking on it.

	For first time installation or if upgrading the hardware to the USB interface box, also do the following:

	For systems that connect to the computer via a USB port (supplied from April 2011):

		Run (double click) the file named icalsetup.exe on the CDROM. Note,do this before
		connecting the USB cable. Follow the instructions on the screen to install the
		InstaCal program.

		Connect the USB cable between computer and interface box. Wait for the data-acquisition
		device to be detected by Windows and for the hardware to be installed. It is important
		to do this before starting InstaCal. If the Windows New Hardware Wizard opens, When
		asked "Can Windows connect to Windows Update to search for software?", select "No, not
		this time". On the next screen, select "Install the software automatically (Recommended)".
		
		Start the InstaCal program from the Measurement Computing folder in All Programs
		from the Windows start menu. The data-acquisition device will be automatically detected
		and added to the config file. The program can then be closed. Note, if a different USB
		data-acquisition interface box is used at any time, InstaCal will have to be run to
		change the config file.

	For systems that use the PCMCIA card (pre April 2011):


		Install the data acquisition card software by running (double clicking) the file
		named pccgosetup on the CDROM. Note, do this before inserting the card into the slot
		on the laptop. Follow the instructions on the screen to install the drivers.

		Restart the laptop.

		Insert the data-acquisition card.

		Follow the instructions on screen to install the drivers for the card.
		When asked "Can Windows connect to Windows Update to search for software?", select
		"No, not this time". On the next screen, select "Install the software automatically (Recommended)".


	A folder called "Free Stroke Analyser" will be created on the C: hard drive

	The Free Stroke Analyser can be started by running the fsa.exe file
	Sometimes the Windows security settings may prevent files from being installed. If you find there is no fsa.exe file in the
	C:\Free Stroke Analyser folder you will need to copy this and the pccgo32.dll file from the downloaded files location to the
	C:\Free Stroke Analyser folder.

	(A shortcut to the fsa.exe file can be put on the desktop for convenience)

	The User's Manual and training presentation will also be copied into the "Free Stroke Analyser" folder

	A folder called "Data Files" will be created in the "Free Stroke Analyser" folder.
	This is provided to copy and keep any data files. (SEE THE USERS MANUAL FOR HOW TO SET UP FOLDERS FOR PLANT, LINE AND BODYMAKERS)


2.	To install or update "Free Stroke Analyser" for analysis usage only (i.e. not for making measurements) on a shared drive: 
	(The software can then be used from any computer on the network)	

		
	Copy the fsa.exe, pccgo32.dll and cbw32.dll files into the required folder.
	
	
	Also copy the User's Manual and Training presentation files if required.

	